AC
Product
AC10
23
CVEs
0
On KEV
9.8
Max CVSS
0
New 30D
Severity mix
Critical 13High 10Medium 0Low 0
Watch
Add AC10 to your stack to get only the CVEs that touch what you run.
| CVE | CVSS | Published | Summary · affected versions |
|---|---|---|---|
| CVE-2025-5629 | 9.8 | Jun 5 | Tenda AC10 HTTP SetPptpServerCfg formSetPPTPServer buffer overflow Affected: 15.03.06.0; 15.03.06.1; 15.03.06.2; 15.03.06.3; 15.03.06.4; 15.03.06.5; +34 more |
| CVE-2024-2856 | 9.8 | Mar 24 | Tenda AC10 SetSysTimeCfg fromSetSysTime stack-based overflow Affected: 16.03.10.13; 16.03.10.20 |
| CVE-2023-45481 | 9.8 | Nov 29 | Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the firewallEn parameter in the function SetFirewallCfg Affected: us_ac10v4.0si_v16.03.10.13_cn |
| CVE-2023-40901 | 9.8 | Aug 24 | Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at url /goform/setMacFilterCfg Affected: v4_us_ac10v4.0si_v16.03.10.13_cn |
| CVE-2023-38931 | 9.8 | Aug 7 | Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13… Affected: V1.0 V15.03.06.23; v4.0 V16.03.10.13 |
| CVE-2023-38935 | 9.8 | Aug 7 | Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the… Affected: v4.0 V16.03.10.13 |
| CVE-2023-38936 | 9.8 | Aug 7 | Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205… Affected: V1.0 V15.03.06.23 |
| CVE-2023-38937 | 9.8 | Aug 7 | Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10… Affected: V1.0 V15.03.06.23; v4.0 V16.03.10.13 |
| CVE-2023-37716 | 9.8 | Jul 14 | Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page… Affected: v.1.0 |
| CVE-2023-37717 | 9.8 | Jul 14 | Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page… Affected: V1.0, |
| CVE-2023-37710 | 9.8 | Jul 10 | Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the wpapsk_crypto parameter in the fromSetWirelessRepeat function Affected: V15.03.06.47 |
| CVE-2023-37711 | 9.8 | Jul 10 | Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the deviceId parameter in the saveParentControlInfo function Affected: V15.03.06.47 |
| CVE-2023-37144 | 9.8 | Jul 7 | Tenda AC10 v15.03.06.26 was discovered to contain a command injection vulnerability via the mac parameter in the function formWriteFacMac Affected: v15.03.06.26 |
Showing 13