FL
Product
Factorytalk Linx
14
CVEs
0
On KEV
9.8
Max CVSS
0
New 30D
Severity mix
Critical 4High 9Medium 1Low 0
Watch
Add Factorytalk Linx to your stack to get only the CVEs that touch what you run.
| CVE | CVSS | Published | Summary · affected versions |
|---|---|---|---|
| CVE-2020-27251 | 9.8 | Nov 26 | A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior Affected: through 6.11 |
| CVE-2020-12001 | 9.8 | Jun 15 | FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later,… Affected: 6.00; 6.10; 6.11 |
| CVE-2025-7972 | 9.1 | Aug 14 | Rockwell Automation FactoryTalk® Linx Network Browser Security Bypass Vulnerability Affected: before 6.50 |
| CVE-2023-29464 | 9.1 | Oct 13 | FactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets Affected: 6.20; 6.30 |
| CVE-2020-11999 | 8.1 | Jun 15 | FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later,… Affected: 6.00; 6.10; 6.11 |
| CVE-2025-9067 | 7.8 | Oct 14 | Rockwell Automation FactoryTalk® Linx Privilege Escalation Vulnerabilities Affected: before 6.50 |
| CVE-2025-9068 | 7.8 | Oct 14 | Rockwell Automation FactoryTalk® Linx Privilege Escalation Vulnerabilities Affected: before 6.50 |
| CVE-2020-5802 | 7.5 | Dec 29 | An attacker-controlled memory allocation size can be passed to the C++ new operator in RnaDaSvr.dll by sending a specially crafted ConfigureItems message to TCP port 4241 Affected: through 6.11 |
| CVE-2020-5801 | 7.5 | Dec 29 | An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in… Affected: through 6.11 |
| CVE-2020-27255 | 7.5 | Nov 26 | A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior Affected: through 6.11 |
| CVE-2020-27253 | 7.5 | Nov 26 | A flaw exists in the Ingress/Egress checks routine of FactoryTalk Linx Version 6.11 and prior Affected: through 6.11 |
| CVE-2020-12005 | 7.5 | Jun 15 | FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later,… Affected: 6.00; 6.10; 6.11 |
| CVE-2020-12003 | 7.5 | Jun 15 | FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later,… Affected: 6.00; 6.10; 6.11 |
| CVE-2020-5806 | 5.5 | Dec 29 | An attacker-controlled memory allocation size can be passed to the C++ new operator in the CServerManager::HandleBrowseLoadIconStreamRequest in messaging.dll Affected: through 6.11 |
Showing 14