Sigma Spectrum Infusion System Firmware
10
CVEs
0
On KEV
9.8
Max CVSS
0
New 30D
Severity mix
Critical 8High 0Medium 1Low 1
Watch
Add Sigma Spectrum Infusion System Firmware to your stack to get only the CVEs that touch what you run.
| CVE | CVSS | Published | Summary · affected versions |
|---|---|---|---|
| CVE-2020-12047 | 9.8 | Jun 29 | The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in a factory-default wireless configuration enables an… Affected: 8.0 |
| CVE-2020-12045 | 9.8 | Jun 29 | The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet service on Port 1023… Affected: 8.0 |
| CVE-2020-12043 | 9.8 | Jun 29 | The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when configured for wireless networking the FTP service operating on the WBM remains operational until the WBM is… Affected: 8.0 |
| CVE-2020-12040 | 9.8 | Jun 29 | Sigma Spectrum Infusion System v's6.x (model 35700BAX) and Baxter Spectrum Infusion System Version(s) 8.x (model 35700BAX2) at the application layer uses an unauthenticated… Affected: 6.0 through 6.05; 8.0 |
| CVE-2014-5433 | 9.8 | Mar 26 | An unauthenticated remote attacker may be able to execute commands to view wireless account credentials that are stored in cleartext on Baxter SIGMA Spectrum Infusion System… Affected: 6.05 |
| CVE-2014-5432 | 9.8 | Mar 26 | Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 is remotely accessible via Port 22/SSH without authentication Affected: 6.05 |
| CVE-2014-5434 | 9.8 | Mar 26 | Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 has a default account with hard-coded credentials used with the… Affected: 6.05 |
| CVE-2020-12041 | 9.4 | Jun 29 | The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) telnet Command-Line Interface, grants access to sensitive data stored on the WBM that permits temporary… Affected: 8.0 |
| CVE-2014-5431 | 6.8 | Mar 26 | Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 contains a hard-coded password, which provides access to basic… Affected: 6.05 |
| CVE-2020-12039 | 2.4 | Jun 29 | Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when… Affected: 6.0 through 6.05; 8.0 |