TA
Product
Terra AC wallbox
by ABB · last CVE Nov 28, 2025
3
CVEs
0
On KEV
6.1
Max CVSS
0
New 30D
VulnerabilityMedium
ABB Terra AC Wallbox
View CSAF Summary ABB is aware of vulnerabilities in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could cause the pollution of heap memory which potentially takes remote control of the product and performs a write operation to the flash memory to alter the firmware behavior. The following versions of ABB Terra AC Wallbox are affected: Terra AC wallbox (JP) <=1.8.33, 1.8.36 (CVE-2025-10504, CVE-2025-12142, CVE-2025-12143) CVSS Vendor Equipment Vulnerabilities v3 6.1 ABB ABB Terra AC Wallbox Heap-based Buffer Overflow, Buffer Copy without Checking Size of Input ('Classic Buffer Overflow'), Stack-based Buffer Overflow Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-10504 There is potential risk to pollute the memory when developing apps which has used to communicate with charger according to self-defined protocol if developers don’t strictly follow the field length which has not been validated in firmware. View CVE Details Affected Products ABB Terra AC Wallbox Vendor: ABB Product Version: ABB Terra AC wallbox (JP) <=1.8.33 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product version; apply the followin...