CVE-2026-8045
CWE-611 Improper Restriction of XML External Entity Reference vulnerability exists that could cause information disclosure of server-side file contents when an attacker with a…
6.5
CVSS
0.2%
EPSS
No
On KEV
Description
CWE-611 Improper Restriction of XML External Entity Reference vulnerability exists that could cause information disclosure of server-side file contents when an attacker with a Data Center Expert user account submits crafted XML payloads to SOAP service endpoints.
CVSS vector
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Attack vector
Network
Complexity
Low
Privileges
Low
User interaction
None
Confidentiality
High
Integrity
None
Availability
None
Scope
Unchanged
Exploitation
Is it being used?
Exploit prediction (EPSS)0.2% · higher than 14% of CVEs
Exploited in the wildNo evidence yet
CISA KEVNot listed
Ransomware campaign useNot known
Affected products
Which versions
EI
EcoStruxure™ IT Data Center Expert · Schneider Electric
v9.1.1 and Prior · source: vendor
SD
Struxureware Data Center Expert · Schneider-electric
before 9.1.2 · source: NVD
In the news
ThreatIntelMedium
Schneider Electric EcoStruxure IT Data Center Expert
View CSAF
Summary
Schneider Electric is aware of a vulnerability in its EcoStruxure™ IT Data Center Expert. The EcoStruxure™ IT Data Center Expert product is a scalable monitoring software that collects, organizes, and distributes critical device information providing a comprehensive view of equipment. Failure to apply the remediation provided below may risk information disclosure.
The following versions of Schneider Electric EcoStruxure IT Data Center Expert are affected:
EcoStruxure IT Data Center Expert vers:intdot/<=9.1.1, 9.1.2 (CVE-2026-8045)
CVSS
Vendor
Equipment
Vulnerabilities
v3 6.5
Schneider Electric
Schneider Electric EcoStruxure IT Data Center Expert
Improper Restriction of XML External Entity Reference
Background
Critical Infrastructure Sectors: Information Technology, Critical Manufacturing, Energy
Countries/Areas Deployed: Worldwide
Company Headquarters Location: France
Vulnerabilities
Expand All +
CVE-2026-8045
CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause information disclosure of server-side file contents when an attacker with a Data Center Expert user account submits crafted XML payloads to SOAP service endpoints
View CVE Details
Affected Products
Schneider Electric EcoStruxure IT Data Center Expert
Vendor: Schneider Electric
Product Version: EcoStruxure IT Data Center Expert (Formerly k...
Jun 30, 2026·CISA Advisories
Affected product
EI
EcoStruxure™ IT Data Center Expert
Schneider Electric
References
NVD
https://nvd.nist.gov/vuln/detail/CVE-2026-8045
CVE.org
https://www.cve.org/CVERecord?id=CVE-2026-8045
Vendor Advisory
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-160-01.pdf
More from EcoStruxure™ IT Data Center Expert
9.5
CVE-2025-50121
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause unauthenticated remote code execution…
8.9
CVE-2025-50122
A CWE-331: Insufficient Entropy vulnerability exists that could cause root password discovery when the password generation algorithm is reverse engineered with access to…
7.2
CVE-2025-50124
A CWE-269: Improper Privilege Management vulnerability exists that could cause privilege escalation when the server is accessed by a privileged account via a console and…
7.2
CVE-2025-50123
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause remote command execution by a privileged account when the server is…
6.3
CVE-2025-50125
A CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthenticated remote code execution when the server is accessed via the network with…