High severity · published Oct 23, 2024
CVE-2024-10280
Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference
7.5
CVSS
0.8%
EPSS
No
On KEV
Description
A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Confidentiality
None
Integrity
None
Availability
High
Scope
Unchanged
Exploitation
Is it being used?
Exploit prediction (EPSS)0.8% · higher than 57% of CVEs
Exploited in the wildNo evidence yet
CISA KEVNot listed
Ransomware campaign useNot known
Affected products
Which versions
AC
AC10 · Tenda
20241022 · source: vendor
AC
AC10U · Tenda
20241022 · source: vendor
AC
AC1206 · Tenda
20241022 · source: vendor
AC
AC15 · Tenda
20241022 · source: vendor
AC
AC18 · Tenda
20241022 · source: vendor
AC
AC500 · Tenda
20241022 · source: vendor
AC
AC6 · Tenda
20241022 · source: vendor
AC
AC7 · Tenda
20241022 · source: vendor
AC
AC8 · Tenda
20241022 · source: vendor
AC
AC9 · Tenda
20241022 · source: vendor
AF
Ac10 Firmware · Tenda
16.03.10.13; 16.03.10.20; 16.03.48.19; 16.03.48.23 · source: NVD, CISA
AF
Ac10u Firmware · Tenda
15.03.06.48; 15.03.06.49 · source: NVD, CISA
References
NVD
https://nvd.nist.gov/vuln/detail/CVE-2024-10280
CVE.org
https://www.cve.org/CVERecord?id=CVE-2024-10280
Third Party Advisory
https://github.com/JohenanLi/router_vuls/blob/main/websReadEvent/websReadEvent.md
Permissions Required
https://vuldb.com/?ctiid.281555
Third Party Advisory
https://vuldb.com/?id.281555
Third Party Advisory
https://vuldb.com/?submit.426417
Product
https://www.tenda.com.cn/
More from AC10
9.8
CVE-2025-5629
Tenda AC10 HTTP SetPptpServerCfg formSetPPTPServer buffer overflow
9.8
CVE-2024-2856
Tenda AC10 SetSysTimeCfg fromSetSysTime stack-based overflow
9.8
CVE-2023-45481
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the firewallEn parameter in the function SetFirewallCfg
9.8
CVE-2023-40901
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at url /goform/setMacFilterCfg
9.8
CVE-2023-38931
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13…
