Critical severity · published Nov 9, 2021
CVE-2021-31346
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All…
9.1
CVSS
2%
EPSS
No
On KEV
Description
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an ICMP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0007)
CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Confidentiality
High
Integrity
None
Availability
High
Scope
Unchanged
Exploitation
Is it being used?
Exploit prediction (EPSS)2.0% · higher than 80% of CVEs
Exploited in the wildNo evidence yet
CISA KEVNot listed
Ransomware campaign useNot known
Affected products
Which versions
AM
Apogee Modular Building Controller Firmware · Siemens
All versions, or not specified · source: NVD
AM
Apogee Modular Equiment Controller Firmware · Siemens
All versions, or not specified · source: NVD
AP
Apogee Pxc Compact Firmware · Siemens
All versions, or not specified · source: NVD
AP
Apogee Pxc Modular Firmware · Siemens
All versions, or not specified · source: NVD
CV
Capital Vstar · Siemens
All versions, or not specified · source: NVD
NN
Nucleus Net · Siemens
All versions, or not specified · source: NVD
NR
Nucleus Readystart V3 · Siemens
before 2017.02.1 · source: NVD
NR
Nucleus Readystart V4 · Siemens
before 4.1.1 · source: NVD
NS
Nucleus Source Code · Siemens
All versions, or not specified · source: NVD
TT
Talon TC Compact Firmware · Siemens
All versions, or not specified · source: NVD
TT
Talon TC Modular Firmware · Siemens
All versions, or not specified · source: NVD
Affected product
AM
Apogee Modular Building Controller Firmware
Siemens
References
NVD
https://nvd.nist.gov/vuln/detail/CVE-2021-31346
CVE.org
https://www.cve.org/CVERecord?id=CVE-2021-31346
cert-portal.siemens.com
https://cert-portal.siemens.com/productcert/html/ssa-044112.html
cert-portal.siemens.com
https://cert-portal.siemens.com/productcert/html/ssa-114589.html
cert-portal.siemens.com
https://cert-portal.siemens.com/productcert/html/ssa-223353.html
cert-portal.siemens.com
https://cert-portal.siemens.com/productcert/html/ssa-620288.html
cert-portal.siemens.com
https://cert-portal.siemens.com/productcert/html/ssa-845392.html
Vendor Advisory
https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf
More from Apogee Modular Building Controller Firmware
9.8
CVE-2021-31886
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE…
9.8
CVE-2021-31884
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE…
9.1
CVE-2021-31890
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All…
9.1
CVE-2021-31889
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All…
9.1
CVE-2021-31345
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All…